Device for testing drives. A testing cycle has been created, where first the housing is tested with air
pressure of 40 bar. After the air measurement, a helium test of the vital part is performed. Finally, a label is produced for a good piece via a printer.
Technical characteristics:
- Piece test on a pallet
- Air tightness test 40bar-5ml/min
- Helium tightness test limit 10-5mbarl/s
- Label printing
- Cycle time 120s/piece